Bobcat 430 VPV010-06 Error Code

VPV010-06 Fault Code Meaning :

FLOW CONTROL P/V (F) ROTATING CCW, Current above normal

VPV010-06 Error Code

FLOW CONTROL P/V (F) ROTATING CCW, Current above normal is the main cause of VPV010-06 error.After seeing this code please, record of service logs, giving you a visualization of completed service and helping you avoid overlooked or repeated repairs. This is especially important for cost savings on repairs for vehicles like dump trucks, where repeated issues with certain components might be covered by the manufacturer warranty.

Bobcat 430 Photo

Tip For 430 Model

If the engine stops, the boom / bucket (attachments) can be lowered to the ground using hydraulic pressure in the accumulator.

The control console must be in the locked down position, and the key switch in the ON position.

Use the control lever to lower the boom.